Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G3RV-SR700-A AC100 PDF.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals
G3RV-SR700-A AC100
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires G3RV-SR700-A AC100 PDF.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 10 A at 5 to 200 VDC.
Rated input voltage: 5 to 24 VDC G3RV-SR700-A AC100 PDF.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current G3RV-SR700-A AC100 datasheet.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3RV-SR700-A AC100 datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.