Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G3ZA-4H403-FLK-UTU PDF.
Realized opening and closing ability with one pole 6 A slim shape
G3ZA-4H403-FLK-UTU
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs G3ZA-4H403-FLK-UTU PDF.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. I/O classification: Temperature inputs.
I/O points: 4 inputs.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
Input specification: Platinum resistance thermometer.
Temperature Input Units for use with MULTIPLE I/O TERMINAL.
Four inputs.
Thermocouples and platinum resistance thermometer models,
are available G3ZA-4H403-FLK-UTU PDF.
Conversion time is only 250 ms for 4 inputs.
The Configurator can be used to calibrate temperatures.
The circuit section can be removed, so rewiring isn’t,
required during maintenance.
DIN track mounting. Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Output Block width is 102 mm).
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation.
Surge suppressor circuit built-in.
Immediate recognition of I/O signal status using,
LED operation indicators.
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1). Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching withh high,
capacity are provided in a compact body without the need of,
radiators G3ZA-4H403-FLK-UTU datasheet. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G3ZA-4H403-FLK-UTU datasheet.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.