I/O classification: Analog output.
I/O points: 4.
I/O connections: Terminal block.
Power supply voltage: 24 VDC.
I/O specification: 0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA.
Analog Input/Output Units Compatible with MULTIPLE I/O TERMINAL.
Input block incorporates connectors that can be easily,
mounted or dismounted G70V-ZID16P PDF. (GT1-AD08MX, GT1-DA04MX)
8 or 4 inputs.
4 outputs
G70V-ZID16P
High resolution of 1/6,000.
High conversion speed of 8 ms/8 points or 4 ms/4 points.
DIN track mounting.
Connector model Terminal Block Model. Classification: LED indicator with test button.
Coil ratings: AC 24, 110, 120, 230, 240; DC 6, 12, 24, 48.
Contact form: SPDT.
Slim and Space-saving Power Plug-in Relay G70V-ZID16P PDF.
Reduces wiring work by 60% when combined with the,
P2RF-@-PU Push-In Plus Socket.
(according to actual OMRON measurements).
Lockable test button models available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic,
function (LED type).
High switching power (1-pole: 10 A). Standard certification: No G70V-ZID16P PDF.
Action indicator: No.
Applicable load of output: DC5 2A ~ 110V.
Input rated voltage: DC4 ~ 24V.
Insulation: photo coupler.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. I/O SSRs That Mount to OMRON’s G7TC I/O Block.
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together,
with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models). Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 4;
Safety outputs, Solid-state outputs: 4; Standard outputs, 4.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals G70V-ZID16P datasheet.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, vverification, standardization and reusage of,
safety control by unique programming software G70V-ZID16P datasheet.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.