Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC G9SA Series PDF.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short
G9SA Series
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws G9SA Series PDF.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Main contact: 3PST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels.
Rated voltage: 24 VDC.
Less Wiring Required with Safety Light G9SA Series PDF.
Curtain.
Sensor connector allows direct connection to OMRON F3SJ.
Safety Light Curtains with PNP outputs.
Reduces wiring and prevents incorrect connection.
Connection to emergency stop switch also supported.
Conforms to EN standards (TÜV approval).
DIN track mounting possible. Standard certification: No.
Insulation: photo coupler.
Zero crossing trigger function.
Action indicator: there.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current G9SA Series datasheet.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G9SA Series datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.