Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 10 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series GRT1-AD2 PDF.
All models feature the same compact dimensions to provide a,
uniform mounting pitch
GRT1-AD2
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) GRT1-AD2 PDF. Item: Basic model.
DPDT: Rated voltage, 12 VAC, 24 VAC, 50 VAC, 100/(110) VAC,
200/(220) VAC, 12 VDC, 24 VDC, 100 VDC, 200 VDC.
Unique Ratchet Mechanism Assures Positive.
Alternate Transfer/Switching Operation.
Each contact in the double-pole contact mechanism performs.
alternate make-brake operation at each pulse input and is thus.
ideal for alternate operation or transfer/switching operation of a motor GRT1-AD2 PDF.
Positive operation is assured due to the unique ratchet mecha nism.
Satisfies dielectric strength of 2,000 VAC.
Low power consumption.
(AC: approx. 6.4 VA; DC: approx. 3.9 W). Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 75 A, 180 to 480 VAC.
Rated input voltage: 100 to 240 VAC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A swittching with high,
capacity are provided in a compact body without the need of,
radiators GRT1-AD2 datasheet. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions GRT1-AD2 datasheet.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.