Supply voltage: 24 VDC.
Time-limit contact: 4PDT(Twin contacts).
Short-time range model (0.1 s to 10 min).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges H5CZ-L8D PDF.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives
H5CZ-L8D Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H5CZ-L8D PDF.
External connections: 8-pin socket.
Input: Signal, Reset (NPN input).
Output: Contact output (time-limit SPDT) H5CZ-L8D PDF.
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Operating modes: Power OFF Delay.
Supply voltage: 100 to 120 VAC.
Control output: Contact output: SPDT.
H3DK-H: S Series (time range: 0.1 to 12 s).
Set two time ranges with each Timer, from 0.1 to 12 seconds for,
the S Series and from 1.0 to 120 seconds for the L Series. Operation/resetting system: Time-limit operation/self-resetting.
Operation mode: ON-delay operation.
Terminal: 8-pin round socket.
Time-limit contact: SPDT.
Instantaneous contact: SPDT.
Mounting: Surface mounting/track mounting; Flush mounting.
DIN-sized (48 x 48, 45 x 75 mm) Timer with H5CZ-L8D datasheet.
Digital Setting and LCD Display.
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
Any desired time can be set digitally within a range from 0.1,
seconds to 9,9900 hrs H5CZ-L8D datasheet.
Four external signal inputs.
ON/OFF indicator for control output and bar indicator for,
remaining time.
Conforms to UL, CSA, and CE marking.