LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K2CM-Q2LS datasheet PDF

OMRON K2CM-Q2LS datasheet PDF

Brand: OMRON
Product model: K2CM-Q2LS
Name: Motor Protective Relay
Sort: PDF datasheet
File language: English
File size: 1.35MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K2CM-Q2LS PDF.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K2CM-Q2LS
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximumCategory: external supply 100mA DC5V type K2CM-Q2LS PDF.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: H; PASS1c, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q2LS PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations. Wiring distance: Standard usage, Wiring cable: 50 m max. Sensing Bands: 10 m max.
Disconnection detection: Not supported.
Socket terminals: Screw Terminal Block P2RF-08/-08-E.
Reliable Sensitive Liquid Sensors,
for Stable Detection of Liquid.
Chemicals with Low Conductivity,
and Water Leakage.
New models available that are compatible with Push,
In Plus Terminal Block Sockets.
UL listed when used with Push-In Plus Terminal,
Block Sockets.
Sensor disconnection detection (K7L-AT50D@/-UD@).
Models for long-distance wiring to 400 m.
Ribbon Electrode Bands and Point Sensors available. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, lload, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q2LS datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equippped with the sub pressure gauge for monitoring the operation trend K2CM-Q2LS datasheet.
External event inputs can be applied to a variety of measurement and identification
Related products
OMRON
Motor Protective Relay
K2CM-4MA
OMRON Motor Protective Relay K2CM-4MA
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-2H
OMRON Motor Protective Relay K2CM-2H
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q1MA
OMRON Motor Protective Relay K2CM-Q1MA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-2M
OMRON Motor Protective Relay K2CM-2M
Time specification: Inverse type. Current set