OMRON K2CU-F80A-E datasheet PDF

Brand: OMRON
Product model: K2CU-F80A-E
Name: Heater Element Burnout Detector
Sort: PDF datasheet
File language: English
File size: 1.26MB
Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CU-F80A-E PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CU-F80A-E
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-F80A-E PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element K2CU-F80A-E PDF.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operatiion time,
is indicated from the start of operation K2CU-F80A-E datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K2CU-F80A-E datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Heater Element Burnout Detector
K2CU-F10A-D
OMRON Heater Element Burnout Detector K2CU-F10A-D
Control supply voltage: 110 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-P2A-A
OMRON Heater Element Burnout Detector K2CU-P2A-A
Control supply voltage: 100/ 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F80A-DGS
OMRON Heater Element Burnout Detector K2CU-F80A-DGS
Control supply voltage: 110 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-P1A-A
OMRON Heater Element Burnout Detector K2CU-P1A-A
Control supply voltage: 100/ 200 VAC With vo