Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-CNB-A-DRT1 AC/DC24V PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-CNB-A-DRT1 AC/DC24V
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-CNB-A-DRT1 AC/DC24V PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Function: Temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22 K3HB-CNB-A-DRT1 AC/DC24V PDF. 5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the startt of operation K3HB-CNB-A-DRT1 AC/DC24V datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-CNB-A-DRT1 AC/DC24V datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.