Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Linear: current; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse K3HB-SSD-CPAC21 AC100-240 PDF.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display
K3HB-SSD-CPAC21 AC100-240
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the increase or decrease of pulse is 3Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control K3HB-SSD-CPAC21 AC100-240 PDF.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output K3HB-SSD-CPAC21 AC100-240 PDF.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and ccyclic control K3HB-SSD-CPAC21 AC100-240 datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-SSD-CPAC21 AC100-240 datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).