OMRON K3HB-VLC-BBCD1 AC100-240 datasheet PDF

Brand: OMRON
Product model: K3HB-VLC-BBCD1 AC100-240
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-BBCD1 AC100-240 PDF K3HB-VLC-BBCD1 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety ofCategory: external supply 100mA DC10V K3HB-VLC-BBCD1 AC100-240 PDF.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-BBCD1 AC100-240 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trendTime specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-BBCD1 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-VLC-BBCD1 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Voltage and current panel meter
K3HB-XVD-ABCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-ABCD1 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVA-BCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-BCD1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-ABCD1 AC100-240
OMRON Rotating pulse meter K3HB-RNB-ABCD1 AC100-240
Input type: NPN/ voltage pulse input type. E