LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-VLC-CPBC21 AC/DC24V datasheet PDF

OMRON K3HB-VLC-CPBC21 AC/DC24V datasheet PDF

Brand: OMRON
Product model: K3HB-VLC-CPBC21 AC/DC24V
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 1 to 2 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-VLC-CPBC21 AC/DC24V PDF.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-VLC-CPBC21 AC/DC24V
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-VLC-CPBC21 AC/DC24V PDF. Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-VLC-CPBC21 AC/DC24V PDF.
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-VLC-CPBC21 AC/DC24V datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-VLC-CPBC21 AC/DC24V datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC21 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Time interval table
K3HB-PPB-CPAC21 AC/DC24V
OMRON Time interval table K3HB-PPB-CPAC21 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC11 AC100-240
Category: external supply 100mA DC10V. Input