OMRON K3HB-VLC-FLK3BT11 AC100-240 datasheet PDF

Brand: OMRON
Product model: K3HB-VLC-FLK3BT11 AC100-240
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-VLC-FLK3BT11 AC100-240 PDF.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-VLC-FLK3BT11 AC100-240
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-VLC-FLK3BT11 AC100-240 PDF. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-VLC-FLK3BT11 AC100-240 PDF.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-VLC-FLK3BT11 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-FLK3BT11 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-AT11 AC100-240
OMRON Time interval table K3HB-PNB-AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XVD-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-FLK1AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Load sensor, mV instrument
K3HB-VLC-BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-BT11 AC100-240
Category: external supply 100mA DC10V. Input