An Ideal Indicator for OK/NG Judgements in Automated and,
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
Easy recognition of judgement results using color display that can be switched,
between red and green.
Equipped with a position meter for monitoring operating status trends K3HB-VLC-L2ET11 AC/DC24 PDF.
External event input allows use in various measurement and discrimination, applications
K3HB-VLC-L2ET11 AC/DC24
Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC,
power takeoff also available.).
Series expanded to include DeviceNet models.
Short body with depth of only 95 mm (from behind the front panel), or 97 mm,
for DeviceNet models K3HB-VLC-L2ET11 AC/DC24 PDF.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
Capable of high-speed sampling at 50 times per second (20 ms).
• Easy-to-set two-point scaling allows conversion and display of any,
user-set values. Input type: high speed response type K3HB-VLC-L2ET11 AC/DC24 PDF.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only 95mmType: Medium-sensitivity models.
Sensed current: 500 mA/1,000 mA(switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
eleectrical devices K3HB-VLC-L2ET11 AC/DC24 datasheet.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutuually compatible K3HB-VLC-L2ET11 AC/DC24 datasheet.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease.