Power supply voltage: 100 to 240 VAC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids K3HB-XAD-A1 AC/DC24 PDF
K3HB-XAD-A1 AC/DC24
Prevents chattering of relay contacts that occurs with ripples.
Easy wiring with ferrules.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA K3HB-XAD-A1 AC/DC24 PDF.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time K3HB-XAD-A1 AC/DC24 PDF.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable from 10msCategory: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputTime specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-XAD-A1 AC/DC24 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAD-A1 AC/DC24 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.