LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XVD-FLK3AT11 AC100-240 datasheet PDF

OMRON K3HB-XVD-FLK3AT11 AC100-240 datasheet PDF

Brand: OMRON
Product model: K3HB-XVD-FLK3AT11 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-XVD-FLK3AT11 AC100-240 PDF.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-XVD-FLK3AT11 AC100-240
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-XVD-FLK3AT11 AC100-240 PDF. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
AC 200, 220, 230, 240, AC 115, 127, 133, 138.
Ideal for 3-phase voltage asymmetry.
monitoring for industrial facilities and equipment.
Monitor voltage asymmetry, phase sequence, and phase loss,
for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K3HB-XVD-FLK3AT11 AC100-240 PDF.
One SPDT output relay, 6 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Model: DGR-H (67G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit wwith 2 relay elements K3HB-XVD-FLK3AT11 AC100-240 datasheet.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-XVD-FLK3AT11 AC100-240 datasheet.
2 stage cross terminal stand with cover with convenient wiring.
Related products