Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AB-VW3 AC200/230V PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8AB-VW3 AC200/230V
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-VW3 AC200/230V PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three K8AB-VW3 AC200/230V PDF.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type: Medium-sensitivity models.
Sensed current: 100 mA/200 mA (switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices K8AB-VW3 AC200/230V datasheet.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutuually compatible K8AB-VW3 AC200/230V datasheet.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease.