Brand: OMRON
Product model: K8DS-PA2
Name: Three-phase Asymmetry and Phase-sequence Phase-loss Relay
Sort: PDF datasheet
File language: English
File size: 0.99MB
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8DS-PA2 PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8DS-PA2
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8DS-PA2 PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note K8DS-PA2 PDF. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply volttage: AC100 ~ 240V K8DS-PA2 datasheet.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the coloor, can switch the green / Red 2 kinds of color display K8DS-PA2 datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input
Related products
OMRON
CJ-series Power Supply Unit
CJ1W-PA202
OMRON CJ-series Power Supply Unit CJ1W-PA202
Power supply voltage: 100 to 240VAC. Output
OMRON
Power Supply Module
C200HW-PA204S
OMRON Power Supply Module C200HW-PA204S
Model: C200HW-PA204S. Supply voltage: 100 to