Structure: upper end mounting insert / solder terminal.
Contact form: 4PDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V) LY4-0 PDF. Compact, Economical Plug-in Type Voltage.
Sensing Relay
LY4-0
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal.
Wide voltage setting range with fine setting capability LY4-0 PDF. Detected voltage: DC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal LY4-0 PDF.
Wide voltage setting range with fine setting capability. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Models with CR circuits for coil surge absorption,
(AC coil specification only).
Number of poles: 2.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup alsso includes models that are compliant,
with the LR and VDE safety standards LY4-0 datasheet.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) LY4-0 datasheet.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).