Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 100 W.
Output voltage: 24 V.
Output current: 4.5 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) SHL-W55 PDF.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
SHL-W55
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) SHL-W55 PDF.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Power ratings: 50 W.
Output voltage: 12 V.
Output current: 4.3 A.
Boost current: 6.5 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC SHL-W55 PDF.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 10 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards SHL-W55 datasheet.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) SHL-W55 datasheet.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)