Full closed loop module.
Maximum applicable motor capacity: 0.4kw.
Power supply voltage: three phase AC200V.
Interface: MECHATROLINK- III communication command type (rotary servo motor).
Design sequence: B.
Hardware specification: base mounting type (standard).
Matching (software): no matching (standard) SGDV-8R4D01B PDF.
Matching (parameters): no matching (standard).
Optional modules: full closed loop module
SGDV-8R4D01B
Full closed loop control system is used to control the rotating servo motor.
Please install the servo unit.
Using the position feedback signal which is output by the external encoder (linear grating ruler) installed on the side of the machine to realize the high precision and high response SGDV-8R4D01B PDF.
External encoder capable of corresponding high resolution (linear grating). Sigma -V series servo motor SGMJV.
Rated output: 0.15kw (150W).
Power supply voltage: AC200V.
Serial encoder: 20 bit absolute value (standard).
Design sequence: standard.
Shaft end: straight shaft with keyway, with screw (optional).
Optional: with oil seal, with the brake (DC24V).
Medium inertia.
Instantaneous maximum torque (rating 350%) SGDV-8R4D01B PDF.
Equipped with a high resolution serial encoder (13/20 bit).
Max speed up to 6000r/min.
Variety is complete (50 ~ 750W, with hold brake).
Use example:
Semiconductor manufacturing equipment,
Placement machine,
Punch printed circuit board,
Robot,
Handling machinery,
Food processing machinery.
Rating and specifications:
Rated time: continuous.
Vibration level: V15.
Insulation resistance: DC500V, 10M, or above.
Using ambient temperature: 0 ~ 40 degrees C.
Excitation mode: permanent magnet type.
Installationn method: flange type SGDV-8R4D01B datasheet.
Heat resistance grade: B.
Insulation withstand voltage: AC1500V 1 minutes.
Protection mode: fully enclosed self cooling type IP65 (except shaft through part).
The use of environmental humidity: 20 ~ 80% (not dew) SGDV-8R4D01B datasheet.
Connection mode: direct connection.
Rotation direction: clockwise direction (CCW) rotation at the load side under the direction of rotation.