Specification: three phase 400V.
Power: 0.4KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V 3G2A6-CT001 PDF.
Cooling way: natural wind cooling.
Weight: 1.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ
3G2A6-CT001
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G2A6-CT001 PDF.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice 3G2A6-CT001 PDF. The commmunication unit can be connected to the CompoNet network with a multi function small transducer MX2 3G2A6-CT001 Manual.
Power supply: through the inverter power supply.
Protection structure: IP20.
From station type: word from station unit (mixed type).
Authentication: Conformance testing via CompoNet OMRON INSTRUCTION SHEET. Specification: three phase 200V.
Power: 5.5KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON INSTRUCTION SHEET.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function) OMRON INSTRUCTION SHEET.
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. 3G2A6-CT001 INSTRUCTION SHEET. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 100.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor 3G2A6-CT001 Manual.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.