Inverter input power: 3 phase / single phase AC200V.
Weight: 1.0KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer 3G3MX2-A2055 PDF.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Function name: 3 phase 400V.
Power: 2.2KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage)
3G3MX2-A2055
Built in brake unit (brake resistance needs to be matched).
Weight: 1.9KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept 3G3MX2-A2055 PDF.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNNet) to realize the field bus communication 3G3MX2-A2055 Manual.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard 3G3MX2-A2055 PDF.
Frequency output up to 580H. Function name: 3 phase 400V.
Power: 15KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 5.2KG.
Dimension (w * h) 296mm *:180 OMRON INSTRUCTION SHEET.
Outline dimension (deep):175mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat OMRON INSTRUCTION SHEET. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Frequency converter input power: 3 phase AC400V.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more.
Used to supppress harmonic currents generated by a transducer OMRON INSTRUCTION SHEET 3G3MX2-A2055 INSTRUCTION SHEET.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Power supply: 3 phase 3 line rated volltage 500V AC 3G3MX2-A2055 Manual.
Rated current: 12A.
Weight: 0.9KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.