LK166
Home >> Download >> OMRON >> Manual Download >> OMRON 3G3MX2-A4075-ZV1 Quick Reference Guide PDF

OMRON 3G3MX2-A4075-ZV1 Quick Reference Guide PDF

Brand: OMRON
Product model: 3G3MX2-A4075-ZV1
Name: Rotary Pulse Meter
Sort: Quick Reference Guide
File language: English
File size: 1.93MB
JX / MX / RX seriesFunction name: 3 phase 200V.
Power: 0.4KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) 3G3MX2-A4075-ZV1 PDF.
Built in brake unit (brake resistance needs to be matched).
Weight: 1.1KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):122.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3MX2-A4075-ZV1
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat 3G3MX2-A4075-ZV1 PDF. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 400V.
Power: 4.0KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.1KG.
Dimension (w * h) 128mm *:140 3G3MX2-A4075-ZV1 PDF.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200% OMRON Quick Reference Guide.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop leevel 0 standard 3G3MX2-A4075-ZV1 Manual.
Frequency output up to 580H. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.3KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer OMRON Quick Reference Guide.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Inverter input power: 3 phase / single phase AC200V.
Weight: 7.0KG.
Standard applicable line diameter: 38 square mm or more.
Used to suppress harmonic currents generated by a transducer OMRON Quick Reference Guide.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Function name: three phase 400V.
Power: 1.5KW.
Maximum output voltage: three phase 380 ~ 480VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced cooling.
Weight: 1.2kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
33Hz provides more than 150% torque output 3G3MX2-A4075-ZV1 Quick Reference Guide.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal outpput function for controlling external brake action 3G3MX2-A4075-ZV1 Manual.
Software setting operation mode, no need to connect the control line can be used for speed control.
Related products
OMRON
Multi function small frequency converter
3G3MX2-A2037-ZV1
OMRON Multi function small frequency converter 3G3MX2-A2037-ZV1
Function name: 3 phase 200V. Power: 3.7KW. Ra
OMRON
Multi function small frequency converter
3G3MX2-A4022-ZV1
OMRON Multi function small frequency converter 3G3MX2-A4022-ZV1
Function name: 3 phase 400V. Power: 2.2KW. Ra
OMRON
Multi function small frequency converter
3G3MX2-A2002-ZV1
OMRON Multi function small frequency converter 3G3MX2-A2002-ZV1
Function name: 3 phase 200V. Power: 0.2KW. Ra
OMRON
Multi function small frequency converter
3G3MX2-A4150-ZV1
OMRON Multi function small frequency converter 3G3MX2-A4150-ZV1
Function name: 3 phase 400V. Power: 15KW. Rat