I/O capacity: 2.048 pts (6, 144 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Name: DeviceNet Master Module C200HW-COM02-V1 PDF.
Model: C200HW-DRM21-V1.
Baud rate: 500, 250, or 125 kbps (selectable)
DeviceNet Master Unit
The DeviceNet Master Unit Is a Multi-vendor Bus Conforming to the DeviceNet.CV500-SL CPU Bus Unit for Com SYSMAC LINK Unit SYSMAC LINK Unit (optical) CV500-SLK11
C200HW-COM02-V12 Platinum resistance thermometer inputs -40 to 250 °C and one output -10 to 10V, 4 to 20 mAModel: C200H-MR433.
Description: RAM, 4K words, battery back-up.with clock (CPU21, CPU23 only) C200HW-COM02-V1 PDF. I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs C200HW-COM02-V1 PDF.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA C200HW-COM02-V1 Manual.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point) OMRON HOST CONNECTION MANUAL.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 OMRON HOST CONNECTION MANUAL. 58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals OMRON HOST CONNECTION MANUAL. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced C200HW-COM02-V1 HOST CONNECTION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee C200HW-COM02-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.