Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking) CJ1G-CPU43P PDF.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CJ1G-CPU43P
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CJ1G-CPU43P PDF. Model : C500-PS221.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5VDC.Model: C200H-OC225.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Name: Temperature Sensor Module.
Model: C200H-TS101 CJ1G-CPU43P PDF.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Model: C200H-ID218.
No. of points: 32 pts.
Specifications: 24 VDC.
Weight: 180g max.CPU Bus Cable (Expansion CPU Rack) 0.6 m (L) CV500-CN611Unit ttype: CS1 Special I/O Units CJ1G-CPU43P Manual.
Product name: Analog Input Unit (100 mV) OMRON HOST CONNECTION MANUAL.
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE OMRON HOST CONNECTION MANUAL.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON HOST CONNECTION MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CJ1G-CPU43P HOST CONNECTION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1G-CPU43P Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.