Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block CJ1W-SCU32 PDF.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications
CJ1W-SCU32
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator CJ1W-SCU32 PDF.
Model: CPM2C-16EDM. Units with inputs only.
1 MIL connector.
Inputs: 16 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Name: Analog I/O Slave Units,
(Numerical indicator type)
MIL Connector Type.
Specifications: Analog outputs; 2 outputs CJ1W-SCU32 PDF.
Standards: CE.
"Easy" and "Flexible" system expansion,
wwith linked CC-Link and CompoNet CJ1W-SCU32 Manual.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON PROGRAMMING MANUAL.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type OMRON PROGRAMMING MANUAL.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave OMRON PROGRAMMING MANUAL.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 224V,-- CJ1W-SCU32 PROGRAMMING MANUAL.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1W-SCU32 Manual.