Model: C200H-OD214.
No. of points: 8 pts.
Specifications: 0.8 A, 24 VDC. source type (PNP). with load short protection.Number of inputs: 8 pts.
Input Voltage: 12 to 24V DC CP1E-E10DT-D PDF.
Input Current: 10 mA.UM: 63.2K words.
DM: 6K words.
EM: 6Kx16 banks(96K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks
CP1E-E10DT-D
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.C500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS02-V1 CP1E-E10DT-D PDF. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223.
4-MB memory; w/floating-point processor.Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CP1E-E10DT-D PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON REFERENCE MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
conteent of the error CP1E-E10DT-D Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
2-Wire Transmitter Input Unit.
Input points : 4 inputs OMRON REFERENCE MANUAL.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON REFERENCE MANUAL.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1E-E10DT-D REFERENCE MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-E10DT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.