C200H Accessory Programming Console Adapter C200H-BP002.Name: Position Control Module.
Model: C200HW-NC413.
Control method: Open-loop, automatic trapezoid acceleration/deceleration CP1E-N40SDT1-D PDF.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 4.Connects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS01.Model : C500-LK103.
PCF.Output type: Transistor sourcing
CP1E-N40SDT1-D
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 CP1E-N40SDT1-D PDF.
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1 CP1E-N40SDT1-D PDF.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals OMRON PROGRAMMING MANUAL. I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C poort: YES CP1E-N40SDT1-D Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs OMRON PROGRAMMING MANUAL.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON PROGRAMMING MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1E-N40SDT1-D PROGRAMMING MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40SDT1-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.