Product name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Transistor (sinking) CP1L-EM30DT-D PDF.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CP1L-EM30DT-D
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CP1L-EM30DT-D PDF. Name: Bit Slave Units with e-CON Connectors.
Specifications: Outputs; 2 outputs; NPN.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection CP1L-EM30DT-D PDF.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors OMRON OPERATION MANUAL.
Bit-level distribution to support,
essentially any application. Unit type: CS1 Special I/O Units.
Product name: Isolated--type,
Analog Output Unit CP1L-EM30DT-D Manual.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V OMRON OPERATION MANUAL.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON OPERATION MANUAL.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1L-EM30DT-D OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-EM30DT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.