LK166
Home >> Download >> OMRON >> Manual Download >> OMRON CP1L-M60DT-A INSTRUCTIONS REFERENCE MANUAL PDF

OMRON CP1L-M60DT-A INSTRUCTIONS REFERENCE MANUAL PDF

Brand: OMRON
Product model: CP1L-M60DT-A
Name: PLC
Sort: INSTRUCTIONS REFERENCE MANUAL
File language: English
File size: 19.98MB
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output CP1L-M60DT-A PDF.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0 CP1L-M60DT-A2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max CP1L-M60DT-A PDF.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Coonsistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup CP1L-M60DT-A Manual.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals CP1L-M60DT-A PDF. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i OMRON INSTRUCTIONS REFERENCE MANUAL. e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON INSTRUCTIONS REFERENCE MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
SSeven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON INSTRUCTIONS REFERENCE MANUAL CP1L-M60DT-A INSTRUCTIONS REFERENCE MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the locaation and,
content of the error CP1L-M60DT-A Manual. vConnection type: Screw - ST connector.
Description: Controller link repeater unit (wire to graded-index glass fibre).
Related products
OMRON
CP1L CPU Unit
CP1L-M30DR-D
OMRON CP1L CPU Unit CP1L-M30DR-D
CPU Unit: CP1L-M CPU Units with 30 Points. S
OMRON
CP1L CPU Unit
CP1L-M40DR-A
OMRON CP1L CPU Unit CP1L-M40DR-A
CPU Unit: CP1L-M CPU Units with 40 Points. S
OMRON
CP1L CPU Unit
CP1L-M30DR-A
OMRON CP1L CPU Unit CP1L-M30DR-A
CPU Unit: CP1L-M CPU Units with 30 Points. S
OMRON
CP1E CPU Units
CP1E-N60DT-A
OMRON CP1E CPU Units CP1E-N60DT-A
Product name: N-type CPU Units with 60 I/O