UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points CPM2C-10CDTM-D PDF.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model : C500-PS221.
100 to 120 VAC or 200 to 240 VAC (selectable)
CPM2C-10CDTM-D
Output ratings: 7 A, 5VDC.CV500-MC Special I/O Unit Motion Control Servo Control 2 axis CV500-MC221.Unit type: CS1 CPU Bus Units.
Product Name: MECHATROLINK-II,
compatible Position Control Unit CPM2C-10CDTM-D PDF.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder,
programming, Control mode:
Position control, speed control,
or torque control; No. of axes: 4.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 CPM2C-10CDTM-D PDF. 36A; 26V, --.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes,
in a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Membeers Association OMRON Operation Guide CPM2C-10CDTM-D Manual. Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A OMRON Operation Guide.
Current consumption: 5 V, 0.21A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection OMRON Operation Guide. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connectionn: Removable terminal block CPM2C-10CDTM-D Operation Guide.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CPM2C-10CDTM-D Manual.
Analog Output Units for converting binary ,