Applicable CPU Units: CQM1H-CPU51/61.
Connection location and number of Units: One Unit only.The Unit must be connected between the Power Supply Unit and the CPU Unit CQM1-CPU42 PDF.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 170 g max.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP217.
8-MB memory; w/o floating-point processor.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units
CQM1-CPU42
Specifications: Output type, Sinking;
I/O points, 64 outputs;
Maximum switching capacity, 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words CQM1-CPU42 PDF.
Current consumption: 5V, 0.17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CQM1-CPU42 PDF.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Name: High-speed Counter Module.
Model: C200H-CT021.
NNumber of axes: 2 axis/Unit CQM1-CPU42 Manual.
Operating modes: 7.
High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources OMRON OPERATION MANUAL. Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
16 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON OPERATION MANUAL. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CQM1-CPU42 OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CQM1-CPU42 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.