C200H Accessory Programming Console Adapter C200H-BP001.Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 2 axes CQM1H-IC101 PDF.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE
CQM1H-IC101
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control CQM1H-IC101 PDF.
Model: CPM2C-20EDR. Units with 20 I/O points.
1 I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.Size: 60mm.
Type: 4 lines.
Lighting voltage: DC24V CQM1H-IC101 PDF.
Color: green.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the OMRON System Manual.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Unit typpe: CS1 Special I/O Units CQM1H-IC101 Manual.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B OMRON System Manual.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON System Manual.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CQM1H-IC101 System Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CQM1H-IC101 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.