Number of inputs: 32 pts.
Input Voltage: 24V DC.
Input Current: 6 mA.Model : C500-LK009-V1.
Maximum of 32 PCs can be linked.Model: CPM2A-20CDR-A. Power supply: AC power supply CS1D-CPU42S PDF.
Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.Model: CPM2C-10C1DTC-D. CPU Unit: Units with 10 I/O points.
2 Fujitsu connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC
CS1D-CPU42S
Output type: sinking transistor.
Internal clock: Yes.Model: C500-BC052(3G2A5-BC052).
5 slots(5 linkable slots).
Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs) CS1D-CPU42S PDF.
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CS1D-CPU42S PDF.
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0 OMRON SYSTEM MANUAL. 3% of F.S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e OMRON SYSTEM MANUAL. g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Model: CPM2A-30CDT-D. Power supply: DC power supply.
Output type: Transistor sinking.
Inputs points: 18 points OMRON SYSTEM MANUAL.
Outputs points: 12 points.Used to attach Hand-held Programming Console to a panel.Unit type: CS1 Speciall I/O Units CS1D-CPU42S Manual.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CS1D-CPU42S SYSTEM MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU42S Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.