Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CS1H-CPU65H PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CS1H-CPU65H
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1H-CPU65H PDF. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 4 to 20mA;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2 CS1H-CPU65H PDF.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 170mA maxx CS1H-CPU65H Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0 OMRON HOST CONNECTION MANUAL. 17*3.
Standards: UC1, N, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Model: C200H-ME431.
Description: EEPROM, 4K words, no clock OMRON HOST CONNECTION MANUAL. Connection type: Screw - Screw.
Description: Controller link repeater unit (wire to wire).Specifications: 1 × RS-232C port + 1 × RS-422/485 port, protocol macro function.Model : CVM1D-PA212.
12A.
Attach two things in the same format in each base Please you OMRON HOST CONNECTION MANUAL. Model: C200H-ID216.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CS1H-CPU65H HOST CONNECTION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1H-CPU65H Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.