Model : C500-PS223.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01.I/O points: 256 pts CS1H-CPU67H PDF.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.CQM1-LK Special I/O Unit I/O LINK MODULE SYSBUS CQM1LK501.Model: C200H-AD003.
Input points: 8.
Voltage input: 1 to 5 V, 0 to 10 V, or –10 to 10 V
CS1H-CPU67H
Current input: 4 to 20 mA.I/O Link of 32 input bits and 32 output bits C200H-CPU21-E CPUs
High Spec, Small Rack Style
The C200H-CPU21-E and C200H-CPU23-E controllers offer increased I/O capacity and the same basic functionality as the OEM versions CS1H-CPU67H PDF. In addition,
these controllers offer an extended instruction set,
expansion. A variety of CPUs are available with various memory and I/O configurations allowing selection based on application requirements.Model : CV500-CN432.
Cable I / O connection CS1H-CPU67H PDF.
40M cable length.Type: Counter inputs, pulse outputs.
12 DC inputs: Yes.
Counter inputs: 2.
Analog inputs: None.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: Yes.Model: C200H-ME432.
Description: EEPROM, 4K words, battery back-up.with clock(CPU21, CPU23 only) OMRON OPERATTION MANUAL CS1H-CPU67H Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1 OMRON OPERATION MANUAL.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON OPERATION MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CS1H-CPU67H OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1H-CPU67H Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.