Model: C500-CN431.
Cable length: 40 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Name: MIL Connector Type.
Specifications: Analog inputs; 4 inputs CS1W-SCB41-V1 PDF.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system
CS1W-SCB41-V1
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1W-SCB41-V1 PDF. C200H Power Supply Aux PS for SLK11 C200H-APS03.
Required when supplying backup power.Output method: Transistor sourcing.
Inputs: ---.
Outputs: 8.Unit classification: CJ1 Special I/O Units CS1W-SCB41-V1 PDF.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Oppen collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only CS1W-SCB41-V1 Manual. ) ,
Max. counting rate, 50kHz.
No. of unit numbers allocated: 4 OMRON HOST CONNECTION MANUAL.
Current consumption: 5V, 0.28A; 24V, --.
Standards: UC1, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions OMRON HOST CONNECTION MANUAL.
The Unit is equipped with 2 Digital Inputs,
2 Digital Outputs and 30 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required OMRON HOST CONNECTION MANUAL. No PC card is provided with the Unit.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outtputs: Open collector,
PNP outputs (pulses) CS1W-SCB41-V1 HOST CONNECTION MANUAL.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output CS1W-SCB41-V1 Manual.