Product name: CJ1M CPU Units; Ethernet function.
Specifications: I/O capacity/Mountable Units Expansion Racks),
320 points/10 Units (No Expansion Rack); Program capacity,
10K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CV500-RT211 PDF. 1 μs;
Ethernet function,YES.
Current consumption: 5v, 0.95A (Seenote 2.) ; 24V,--.
Standards: UC1, N, L, CE
CV500-RT211
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Model: CPM2C-8EDC. Units with inputs only.
1 Fujitsu connectors.
Inputs: 8 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: -- CV500-RT211 PDF. Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CV500-RT211 PDF.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags caan be checked at the Host,
Controller to detect the location and,
content of the error OMRON Macro Reference CV500-RT211 Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 OMRON Macro Reference. 20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON Macro Reference.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CV500-RT211 Macro Reference.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CV500-RT211 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.