C500-IA I/O Unit AC Input 16 pts C500-IA222(3G2A5-IA222).
AC200-240V 10mA.C500-ID Special I/O Unit ID Sensor Unit General Purpose C500-IDS01-V2Number of inputs: 32 pts CVM1-CLK52 (GI CABLE) PDF.
Input Voltage: 24V DC.
Input Current: 4 mA.Protector for CPU bus connector CV500-COV01CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 12; Output, 8
CVM1-CLK52 (GI CABLE)
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet CVM1-CLK52 (GI CABLE) PDF.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Ranges : -10 to + 10V, 0 to 10V, 0 to 5V, or 0 to 20mA CVM1-CLK52 (GI CABLE) PDF.
Power supply : Built-in, DC/DC converter.C500-AD Special I/O Unit Analog Input C500-AD501.
Inpput: 16 pts CVM1-CLK52 (GI CABLE) Manual.
Specification: 0~+5V, 0~+10V, -5~+5V
-10~+10V, 0~+20mA, -20~+20mA.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit OMRON Installation Guide.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON Installation Guide.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling OMRON Installation Guide.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compareed,
with previous systems CVM1-CLK52 (GI CABLE) Installation Guide.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CVM1-CLK52 (GI CABLE) Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.