Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CXONE-AL03D-V4 PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CXONE-AL03D-V4
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CXONE-AL03D-V4 PDF. Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 24 points.
Outputs points: 16 points.Ranges : -10 to + 10V, 0 to 10V, 0 to 5V, or 0 to 20mA.
Power supply : Built-in, DC/DC converter.Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit CXONE-AL03D-V4 PDF.
Specifications: Communications cable,
Wired shielded twisted-pair cable;
Communications type, Data links and,
message service; Duplex support, No.
Max. Units mountable per CPU Unit, 8.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.33A; 26V, -- OMRON Installation Guide.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required OMRON Installation Guide.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Model: CPM2A-60CDT1-D OMRON Installation Guide. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 36 points.
Outputs points: 24 points CXONE-AL03D-V4 Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CXONE-AL03D-V4 Installation Guide.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CXONE-AL03D-V4 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.