Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m E5AC-CX4DSM-004 PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E5AC-CX4DSM-004
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models E5AC-CX4DSM-004 PDF.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring worrk E5AC-CX4DSM-004 PDF E5AC-CX4DSM-004 Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON User's Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON User's Manual.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON User's Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5AC-CX4DSM-004 User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AC-CX4DSM-004 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.