Ontology: basic.
Size: 48 x 96mm.
Type: basic type (1 input)
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current) E5AC-CX2DSM-014 PDF.
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line
E5AC-CX2DSM-014
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation E5AC-CX2DSM-014 PDF.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functionns E5AC-CX2DSM-014 Manual.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program E5AC-CX2DSM-014 PDF. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2 OMRON Advanced Type.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy OMRON Advanced Type.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON Advanced Type E5AC-CX2DSM-014 Advanced Type.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AC-CX2DSM-014 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.