LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5AC-QX2ASM-008 lnstruction Manual (RS-485 CompoWay/F) PDF

OMRON E5AC-QX2ASM-008 lnstruction Manual (RS-485 CompoWay/F) PDF

Brand: OMRON
Product model: E5AC-QX2ASM-008
Name: Digital Counter
Sort: lnstruction Manual (RS-485 CompoWay/F)
File language: English
File size: 2.32MB
Fitting materials: Iron, zinc plating.
Count: 1 .
Accessories: Description, Phillips screws M2.3 × 8,
Spring washer M2.3;
Material, Iron, zinc plating, Iron, zinc plating;
Count, 4; 4 E5AC-QX2ASM-008 PDF.
Applicable sensor (mounting pitch on sensor side): E3C-S10 (7.5).
Page: Dimensions, 12. Sensing method: Through-beam (Emitter + Receiver).
Connection method: Standard M8 connector.
Sensing distance: 15 m E5AC-QX2ASM-008
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models E5AC-QX2ASM-008 PDF.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Small, easy to use.
Detection method: Regression reflection type E5AC-QX2ASM-008 PPDF E5AC-QX2ASM-008 Manual.
Shape: vertical type.
Connection mode: lead wire.
Detection distance: 1 meters of red light.
Output mode: NPN output. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON lnstruction Manual.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON lnstruction Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON lnstruction Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Teemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AC-QX2ASM-008 lnstruction Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AC-QX2ASM-008 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Digital temperature controller
E5AC-QX4DSM-012
OMRON Digital temperature controller E5AC-QX4DSM-012
Size: 96 x 96mm. Control output 1: voltage o
OMRON
Digital temperature controller
E5AC-QX4ASM-010
OMRON Digital temperature controller E5AC-QX4ASM-010
Size: 96 x 96mm. Control output 1: voltage o
OMRON
Digital temperature controller
E5AC-QX2DSM-011
OMRON Digital temperature controller E5AC-QX2DSM-011
Size: 96 x 96mm. Control output 1: voltage o
OMRON
Digital Temperature Controller
E5AC-QX3ASM-810
OMRON Digital Temperature Controller E5AC-QX3ASM-810
Control output 1: Voltage output. Control ou