Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type E5AN-HSS2HH02BD-FLK PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance
E5AN-HSS2HH02BD-FLK
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10 E5AN-HSS2HH02BD-FLK PDF. 5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5AN-HSS2HH02BD-FLK PDF.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
Thhe use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set E5AN-HSS2HH02BD-FLK Manual.
It can be easily set by CS-Thermo (sold separately) OMRON Basic Type. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function OMRON Basic Type.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure OMRON Basic Type.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the theermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5AN-HSS2HH02BD-FLK Basic Type.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5AN-HSS2HH02BD-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.