Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 100 mm (wide view).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly E5AN-R3H03T-W-FLK-N PDF.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2
E5AN-R3H03T-W-FLK-N5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Appearance: Shielded, M12.
Sensing distance: 4 mm E5AN-R3H03T-W-FLK-N PDF.
Model: NO.
Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
with reduced problems due to workpiece collisions.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature. Power supply voltage: DC.
Sensing method: Through-beam (Emitter + Receiver) E5AN-R3H03T-W-FLK-N PDF.
Sensing distance: 5 m.
Output configu ration: NPN.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models) OMRON User's Manual.
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC) OMRON User's Manual.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change OMRON User's Manual.
Can be similar to the feeling of a limit switch installation.
Type: detection of variable terminal plate / DC type.
Shappe: shield E5AN-R3H03T-W-FLK-N Manual.
Detection distance: 20mm.
Output form: NO PNP + NC (dual output). Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the statee of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5AN-R3H03T-W-FLK-N User's Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5AN-R3H03T-W-FLK-N Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.