Brand: OMRON
Product model: E5AR-A4WW-500
Name: PLC Module
Sort: OPERATION MANUAL
File language: English
File size: 3.69MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver) E5AR-A4WW-500 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5AR-A4WW-500
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5AR-A4WW-500 PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
IIncrease the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5AR-A4WW-500 PDF E5AR-A4WW-500 Manual.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. The main body: terminal type, temperature input type OMRON OPERATION MANUAL.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON OPERATION MANUAL.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade OMRON OPERATION MANUAL.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
FFurther performance improvement E5AR-A4WW-500 OPERATION MANUAL.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5AR-A4WW-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.