Protection tube diameter: screw pitch W1/4.
Wire length: 4m.
Core line type: K (CA).
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models E5CC-CX2DUM-000 PDF.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40). Size: DIN 1/16, 48 X 48 x 60mm
E5CC-CX2DUM-000
Power supply voltage: AC100 ~ 240V.
Input type: Platinum resistance.
Alarm points: 1 points.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21 E5CC-CX2DUM-000 PDF. 7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 20 cm E5CC-CX2DUM-000 PDF.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wirring work E5CC-CX2DUM-000 Manual.
Ideal for the thermal input devices of Temperature Controllers OMRON INSTRUCTION MANUAL.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON INSTRUCTION MANUAL.
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output) OMRON INSTRUCTION MANUAL.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5CC-CX2DUM-000 INSTRUCTION MANUAL.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-CX2DUM-000 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.