Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2 E5CC-QX2DSM-003 PDF. ).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None
E5CC-QX2DSM-003
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel E5CC-QX2DSM-003 PDF.
Terminal: M3 terminal.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups E5CC-QX2DSM-003 PDF.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
cconnections to Programmable Controllers E5CC-QX2DSM-003 Manual. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise OMRON INSTRUCTION MANUAL. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input OMRON INSTRUCTION MANUAL.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc OMRON INSTRUCTION MANUAL. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connectiion method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CC-QX2DSM-003 INSTRUCTION MANUAL.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5CC-QX2DSM-003 Manual.
It can be easily set by CS-Thermo (sold separately).