Control output: relay output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit) E5CN-C2MTD-W-500 PDF.
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type
E5CN-C2MTD-W-500
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved E5CN-C2MTD-W-500 PDF.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5CN-C2MTD-W-500 PDF.
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm) OMRON Basic Type. Wire length: 1m.
Screw switch: M6.
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40) OMRON Basic Type. Name: Basic Unit (temperature control) *1.
Poower supply voltage: 24 VDC supplied from the End Unit E5CN-C2MTD-W-500 Manual.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2 OMRON Basic Type.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZAA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5CN-C2MTD-W-500 Basic Type.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E5CN-C2MTD-W-500 Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.